Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta almost 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI to CONNECT to propagate Enumeration Sets

We make use of Enumeration Sets in AF to provide labels to Integer values. We need those also in CONNECT data services to view them as such.
Christian Leroux almost 4 years ago in PI to CONNECT / General 0 No status

Simplify access to objects using REST API

Citizen data scientists, IT professionals and general OCS users need to use REST API methods in 3rd party applications - including Power BI - to access data or explore data using OCS Portal API Console. Typically objects not "custom created - whe...
Guest almost 4 years ago in Developer Resources / CONNECT data services API 0 No status

OCS Community API: Access to Stream Type info for Properties & UOMs

The ability to expose the stream type property and UOMs for a stream shared through community in the API.
Guest almost 4 years ago in Developer Resources / CONNECT data services API 0 No status

PI to CONNECT Installation Footprint

As a PI System Administrator, I would like a way to deploy PI to CONNECT in a secure and manageable way so that it is easy to maintain, and I can trust it is secure. Currently, AVEVA recommends PI to CONNECT be installed on a separate computer fro...
Guest almost 4 years ago in PI to CONNECT 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Specific debug log levels to troubleshoot specific issues

Similar to PI Interfaces (/DB for opcint), adapters should allow setting some additional debugging to troubleshoot specific issues, instead of only allowing a general LogLevel (Information, Trace, Warning, etc.) This would allow for more granular ...
Gabriel Verreault almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Already exists