To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 45 of 5218

Add functionality to the interface to adjust timestamps by a configurable amount

This enhancement would add the ability to adjust timestamps to the PI to PI Interface (Beyond the included options for clock drift and subseconds). Potentially, a setting could be supplied to change the timestamps on all data transferred by a spec...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

"Create or Update Data Reference" through OSIsoft.Powershell

It is already possible to create an instance of an existing AF Element Template by using the powershell cmdlet Add-AFElement with the -AFElementTemplate option. The element is then created in the AF tree, however if there are tag creation rules de...
phsutter over 3 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

Support importing multiple aliases using the KST.INI file during setup

As a PI System Admin, I would like to be able to specify multiple aliases for one PI Server in a KST.INI file that will be used to create a predefined set of PI Servers during a silent install of the PI SDK so that I can ensure that all users have...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

PItoPI should switch from COLD to WARM failover instead of exiting

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, older versions supported COLD failover. In the case of upgrading the interfaces, ...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 2 No status

Search ability in AF Client on more than just element.

It would be nice to be able to search anything when it comes to AF Client. If I wanted to search and find reference to all Motor Speed Attributes.If I wanted to search on where a tag 'Sinusoid' for example was referenced in:Attributes, Analysis', ...
BrentWebsterADM over 2 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

Support DST Transition on Second Granularity in PI SDK

A user tries to retrieve date with timestamp 03-Nov-2018 23:59:59 (1 second before Daylight Saving Time beginning) in PI SMT, but the returned event has a timestamp of 04-Nov-2018 00:59:59. This is because PISDK timezone design is such that it can...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / General 0 Declined

Add ApplyToChildren option to PowerShell cmdlet AddAFSecurity

Cmdlet AddAFSecurity does NOT have an ApplyToChildren setting, causing me to need to add security to all sub-objects: https://docs.osisoft.com/bundle/pi-powershell/page/html/T_OSIsoft_PowerShell_AddAFSecurity.htm RemoveAFSecurity DOES have thi...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

PowerShell Add-PIValue and annotations

Really need to be able to send annotations to PI Tag Values through PowerShell.
Maxime Raguenet over 3 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Source and destination tag mapping list

Customer would like the ability to have PItoPI create a list of tags that includes the FULL name of the source tags, as well as the destination tags they are mapped to.  This will greatly assist in managing tags that are being sent to a remot...