To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 273 of 5194

Data Anomaly EF generation

Generation of EF automatically for data anomaly like bad,out of range,flatlines and spikes. A single click option which crerate EF if the data anomly occurs (based on the preset hi, lo limits) .
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Event Frame Start and End Timestamp relative to trigger

With an event frame analysis I search for production downtimes that are longer than 30 min with the "true for" option or a "TimeGE" function. But in this way I allway loose these 30 min at the beginning of my downtime event. So I would like to be ...
JanWortmann over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Output Acknowledging Event Frame to PI Tags

AF/EF is used to contextualize the OEE Event. However, because reason codes entries does not include the name of the person who entered the code and/or the time it was entered, we leverage ODBC to gain access to the Event Frame record. Due to th...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Set Reason for closed Event Frames when it is PI Point Data Reference through PI Vision

Currently, when the Reason of an Event Frame is set as PI Point Data Reference, its value cannot be changed through PI Vision Event Table. Moreover, if you try to change the Reason of a closed Event Frame and currently another Event Frame is open,...
J.M. Rodríguez over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

have event frames with multiple start triggers match preview results when the parent start time is adjusted during reconciliation

As a PI System admin, I would like event frames with multiple start triggers to match preview results when the parent Event Frame's start time is adjusted during Event Frame reconciliation. Currently we have to take one of the following actions to...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

BI Integrator preserve Column Configuration on Filter Change

When you copy a BI Integrator Job ans change some settings in the Filter all attributes are added to the column view. We remove Attributes that are not needed e.g. Level1 Attributes when we only Need the Level2 Child Attributes. On a change the L...
koettih over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 Declined

Overlapping Time Ranges for Continuous View updates (Rolling Publications)

I wish that the start time of a continuous view update cycle could precede the end time of the last cycle. For example every day query the last 30 days of data and replace rows that have already been written to the target table with the most rece...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 Declined

Publish event view even if there are no matches

I have a need to create event views before a process starts and the event frames are created. Right now, I have to create a dummy event frame in order to publish the view since you cannot publish a view with no matches.
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 Declined

Disable automatic matches in Modify View screen

As a PI View creator with an AF Database with several thousands of elements, I need to disable automatic matches so the GUI would run faster, and when I have finished shaping my data I should be able to enable matches again.
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Unique Output Streams Consumed/Remaining notification

I would like to get notified for Unique Output Streams Consumed or Remaining in PI Integrator Administration page under Licensing.