To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 100 of 5194

BACNet: Add support for Conversion Factor PI Point attribute to PI Interface for BACNet

Add support for Conversion Factor PI Point attribute to PI Interface for BACNet. Note: This was previously Enhancement 118928.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Create a user friendly OPC HDA Tool to replace the current one

No description provided
Gabriel Verreault over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Buffering Manager - add metrics for each buffered interface

When validating/troubleshooting data flow issues, it would be helpful to see metrics on which interfaces are actively sending data to the buffering subsystem via Buffering Manager. If an interface is in a bad state or stopped, it would be obvious ...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Fix PI XMLTool (bundled with PI Interface for OPC XML-DA)

The PI XMLTool that is bundled with the PI Interface for OPC XML-DA does not function with Windows Server 2019 even though the PI Interface for OPC XML-DA itself is documented to function. Can the client tool please be worked on so that it will fu...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

EFGEN multi language support for event frame name

Hi, Existing EFGEN does not seem to support multi language (Double bytes characters) inputs for Event frame name. This result in the event frames names are being recorded in English char only. Would it be possible to implement the multi-langua...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 Declined

Add option to limit time period for 'Last Recorded Value' Data Context

For data such as daily volumes produced, we need exact values from PI and Interpolated data just doesn't fit in this case. So we need to configure such columns with 'Last Recorded Value' Data Context. With this setting we certainly get the last ar...
Guest over 3 years ago in PI Integrators / PI Integrator for SAP HANA 1 Declined

WIS support for TCP Response interface

If trusts are disabled in Data Archive, the TCP Response Interface will generate a logon error every time it performs a TCP request (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000032778). The interface should be updated, ...
mose almost 2 years ago in PI Interfaces / Other Interfaces 0 Evaluating

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters over 3 years ago in PI Interfaces / Other Interfaces 0 No status

DNP3: handle invalid timestamps from the RTU

If the RTU provides a timestamp of 0 when using RTU provided timestamps, which does not conform to the DNP3 spec, allow the option to timestamp the event with PI time or drop the event altogether. Note: This was previously Enhancement 123208.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

When Citect Interface loses connection to a device, throttle errors relating to failed tag reads

OSI PI Citect Interface The interface will log an entry to the message log for every tag that it can't source data for. This is fine for a small number of tags that have not been able to read data from Citect. However, when a Citect Unit (eg PLC)...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status