To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 70 of 5194

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Capture data from ABB 800xA that doesn't follow ISA88

ABB 800xA offers a batch capture mode that is more flexible than ISA88 since it doesn't match all unit procedures to units, but rather acquires them at the beginning of the batch. Currently the interface is designed to only retrieve batches that f...
Alan Izar over 3 years ago in PI Interfaces / Batch Interfaces 3 Declined

Batch Interface for Honeywell Experion

We are in need of a PI Batch/AF Events Interface to store data from Honeywell Experion Batch or Honeywell Procedure Analyst into PI Asset Framework.
Jürgen Schmidt over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Add OPCclient to all PI OPC DA server install kit

In verifying the OPC DA server DCOM setting you need to use the OPCclient to check PI tags values. In the OPC DA server 2017 you need the latest version of OPCclient (was not in OCP client tools) to allow to connect correctly to the OPC DA server ...
davidrosinski over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 4 Declined

Be able to expose AF with PI OPC DA Server

Today PI OPC DA can only expose tags from DA. To have the option to expose information from AF. Both the AF structure and attributes. We are using AF for everything so why not in PI OPC DA.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 3 No status

Delete mode in Wonderware InBatch interface

When run in delete mode for WWInBatch interface, it uses the data source as the system of record--any open batch in SQL will be deleted. However, as abandoned or done  batches are open in WonderWare but closed in PI, the interface may delete ...
Willy Seah Wei Liat over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

Double check window required when deleting an instance in PI Event Frames Interface Manager

As a PI System Admin, I would like to see a confirmation window (acceptation pop-up message), when deleting Interface instances in PI Event Frames Interface Manager. This would minimize the deletion of the instances by error.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Enhance Visibility of Event Frame Generator/Batch Interface History Recovery Status

Currently when running any event frame generator interface (EFGen, PIFTBatch, etc.) in history recovery mode, there is no way to monitor progress of the actual history recovery. The only way to determine status is to check message logs periodicall...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status