To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 75 of 5194

Event Frame Start and End Timestamp relative to trigger

With an event frame analysis I search for production downtimes that are longer than 30 min with the "true for" option or a "TimeGE" function. But in this way I allway loose these 30 min at the beginning of my downtime event. So I would like to be ...
JanWortmann over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Output Acknowledging Event Frame to PI Tags

AF/EF is used to contextualize the OEE Event. However, because reason codes entries does not include the name of the person who entered the code and/or the time it was entered, we leverage ODBC to gain access to the Event Frame record. Due to th...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Set Reason for closed Event Frames when it is PI Point Data Reference through PI Vision

Currently, when the Reason of an Event Frame is set as PI Point Data Reference, its value cannot be changed through PI Vision Event Table. Moreover, if you try to change the Reason of a closed Event Frame and currently another Event Frame is open,...
J.M. Rodríguez over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

have event frames with multiple start triggers match preview results when the parent start time is adjusted during reconciliation

As a PI System admin, I would like event frames with multiple start triggers to match preview results when the parent Event Frame's start time is adjusted during Event Frame reconciliation. Currently we have to take one of the following actions to...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Update 'Modified date' of an event frame when an attribute is filled in manually (for example with reason code)

At this point, only the modified date of an event frame is updated when the event frame is created or when a backfill or recapture is performed. For transferring data to a data lake or warehouse, it would be very useful to see which event frames c...
Bart Van De Gehuchte about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Ability to find the EFGEN configuration server name and interface ID for Event frames

It would be great if we can know from which machine EFGEN interface are configured and the corresponding EFGEN interface Id for a particular event, so it will be easy to troubleshoot the issues occurring in event frame generation.
PradeepKumar Logandurai about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Allow PI OLEDB Enterprise client to specify which member of a PI Data Archive Collective to connect to.

Enable functionality for PI OLEDB Enterprise that will allow the client to specify which member of a PI Data Archive collective they wish to connect to. This functionality has already been enabled for PSE and would like something similar for PI OL...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 0 Declined

Let Start Trigger severity set the EventFrame severity

Currently the Severity of the EF is set on the template. The severity of a start trigger allows to create child events. I want to have the ability to have the severity of the start trigger set the severity of the generated EventFrame. In that way...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 Declined

The "True for" time of event frame generation analyses should not consider the extrapolation after the snapshot event

PI assumes that the value of a PI Point from its snapshot event up to now is equal to the snapshot value. This extrapolation is not necessarily a good representation of what the interpolation will look like when new data arrives. The extrapolatio...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 6 Declined

Event Frames Scalability - For Customer Advisory Lab Scenarios

#of assets (in this specific scenario): 500-1000 EF Count: Generation rate of 25,000/day peak, would like to historize for 1+y = 9,000,000 events+ Attributes: 5-10 attributes/event (static or PI Point) Flat Hierarchy Queries: EF are alarms or ...