Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 61 of 5219

Provide alternative message to 'No value defined"

When querying AF Element Information certain values display: "No value defined." and customer reaction was that there was something not working correctly/error that needed to be investigated. Suggestion was to change text to either show the value ...
Guest about 2 years ago in PI to CONNECT / General 0 No status

Incorporate event frame acknowledgements into the event frame search features

We are now able to acknowledge events via PI Coresight. This information is then stored in the PI AF back end. However, there is currently no way to retrieve this information via PI Datalink. While the EF search panes have a couple of options fo...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 Declined

Manual selection of Event Frame

I would like to select Event Frame/ Event Frames from the Preview in Explore Events task-pane and result returns manually selected Event Frame/ Event Frames only.
Willy Seah Wei Liat over 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 Declined

Export Attachments or Attachment Path Attached to Event Frame Annotations

We are able to currently see annotations for Event Frames but there is no easy way to quickly get a bulk export of Event Frames with Annotations along with what was attached to it, be it file name or path. It would be good to have another column t...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 Declined

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Julian Weber over 2 years ago in PI to CONNECT / General 0 No status

Use PI Server Alternate Display Name in stream naming pattern

The PI Server Alternate Display Name is only used to build the stream IDs. It would be better to use it in the stream naming pattern as well.
Clement Dekeyser about 3 years ago in PI to CONNECT / General 0 No status

Seamless change of PI Server Alternate Display Name

When the PI Server Alternate Display Name is modified, new streams are created to receive live data while historical data remains only in the existing streams. It would be better to automate: the deletion of existing streams the backfilling of new...
Clement Dekeyser about 3 years ago in PI to CONNECT / General 0 No status

More options when searching for PI Points

During a Lighthouse project a customer noted that they have a number of points in their data archive that are no longer on scan. It would be helpful, then, if the PI Point Search facilities in PI to CONNECT allowed use of the ‘scan on/off’ flag so...
Guest over 3 years ago in PI to CONNECT / General 0 No status

Allow setting default security for all streams resulting from a given transfer

CONNECT may have multiple PI to CONNECT transfers coming from different Data Archives. The DAs data may have different security requirements. To facilitate managing this in CONNECT, there should be a way to set default security for streams (and as...
Brian Deslatte over 2 years ago in PI to CONNECT / General 0 No status

Automate dataset selection for each PI to CONNECT Agent

We would end up with more than 60+ PI to CONNECT Agents to configure. We have a strong AF hierarchy across our sites and could perfectly prepare a unique AF rootpath to select the relevant dataset to push from PI/AF to CONNECT for each 60+ connect...
Christian Leroux almost 3 years ago in PI to CONNECT / General 1 Future consideration