Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1440 of 5259

UOM field should accept substitution parameters

It would be nice if the UOM field of an AF Attribute would accept substitution parameters. This way if an attribute is a reference to another, the UOMs could also be linked. If the UOM is updated on the source, it would also get updated in the ref...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Include filtering logic in asset analytics

In Asset Analytics, there isn't a way to include a filtering function in a single analytic. For example, you may be calculating run hours on a motor, but there is no way to filter the calculation so that it is only done when the motor is running.
Laurie Dieffenbach over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Add Function to Determine if a Bit is Active in a Word Value

It would be extremely helpful if a function existed within PI AF where could provided a value/tag reference and a bit number to check and see if its active. The function would return a True or False value if that bit is active. Something like the ...
Justin Jackson 4 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Option to ignore the digital state set ID in historical archive record headers and just use the one in the latest or in the point database.

If digital tags are found to be assigned to inappropriate digital state sets, changing the state set does not change historical data since the state set is also held in each archive record header. To correct the historical data, you have to offlin...
AlistairTCO almost 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Use dynamic endpoints to subscribe AF Groups to Notification Rules.

We have several sites, and a corresponding AF Group with personnel local to each site. We would like to configure the AF Element Template for sites to send a daily notification to the corresponding group for each site. This can only be done by add...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Notifications 0 No status

Add a Concat() function that can be nested into the other available functions for string builder

When using string builder attributes to dynamically generate specific values, additional attributes need to be created whenever concatenation of multiple attribute values is part the the logic. For example when using a string builder to generate a...
Randy Giguere 12 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Add option to clear buffer errors to the Buffering Manager

Currently users have to use the command line tools to clear buffer point errors. It would be useful and enhance O&M if these errors could be cleared directly from the UI rather than just viewed.Bonus points for allowing users to clear all, mul...
Shawn McNabb almost 2 years ago in AVEVA™ PI Server / System Management 0 No status

Executing query or stored procedure directly from AF analysis

Currently you can add a query or stored procedure to the library in AF. From there you can retrieve data to be used in an attribute via table lookup. What I am looking for however, is to be able to directly execute a stored procedure from an analy...
David W 8 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Allow administrators to select a subset of their permissions while interacting with vision

When configuring data access permissions in PI, it is difficult to test whether you've "gotten it right" using an account with admin permissions because the admin account usually has access to everything. I have worked with other systems where use...
Kevin Wood about 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status

Default Multi-State Colors by Enumeration Set

Please add the ability to set default multi-state configurations (including blinking/hidden/transparent) by enumeration set. Manually modifying/validating each value is time-consuming and presents the opportunity for inconsistencies across the org...
Kelsey Bobeck over 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status