To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 51 of 5219

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest over 3 years ago in AVEVA™ Adapters / General 0 Tell us more

Disable the recalculation auto when filtering the result

The problem is that after the calculations of PI Data Link Functions, I want to review the results by applying Filtering to the rows, but as soon as I set up the Filter, Excel immediately runs the calculation again. I have to wait until the calcu...
Guest 11 months ago in AVEVA™ PI DataLink™ / Settings 0 No status

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / General 1 No status

PI System Explorer shows times in US-American format, despite Windows being German

My Windows UI is set to English for all text-matters. However all region formats (dates, comma-versus-period-decimal-symbol and so on is set to German) Most programs respect these settings. However PI System Explorer displays all date/time formats...
Guest 11 months ago in AVEVA™ PI DataLink™ / Settings 0 No status

Option to disable DataLink automatic grouping

As a creator of DataLink spreadsheets, I would like to have the option to disable DataLink automatic grouping so that I can apply an input to one function (ex. filter expression, conversion factor, etc.) without it being applied to the entire grou...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 1 No status

Provide a streamlined way to rename streams and push the changes to the endpoint

The current process forces the user to modify the adapter configuration (DataSource for the prefix, DataSelection for the stream name) and the endpoint (PIDA, OCS). The adapter should support modifying directly the stream name and push those chang...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 1 Future consideration

Allow users to include or omit element references from searches

As of PI DataLink 2015, element reference paths are returned in addition to the primary element path if they both exist under the search root. Enhance the Search and Asset Filter Search to include or omit element reference paths. Note: This was p...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 0 Declined

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 0 No status

Support Kerberos for adapters on Linux

Adapters are supported on Ubuntu, which also provides support for Kerberos (https://documentation.ubuntu.com/server/explanation/intro-to/kerberos/) Adding Kerberos support would increase the options for deploying adapters securely.
Mike Horrocks 7 months ago in AVEVA™ Adapters / General 0 No status

EdgeCmd "add" data selection with CSV

At the moment the EdgeCmd data selection with a file path is limited to get and set. This means that to perform an update the data selection needs to be exported, modified, and the imported. It would be a great time saver to be able to provide a s...