To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 58 of 5199

trend log objects (BACnet object type 20) available from the connector

BACnet trendlog object present the opportunity to buffer at the edge where the data is collected and to gracefully recover from comms outages if data collection has been impacted. I would suspect the trendlog object could be handled similarly to ...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Include the "Primary Parent" checkbox functionality under PSE's "Change Reference Type" dialog in PI Builder

In PSE, you can right click an element reference > Convert > Change Reference Type... and have the option to make your current element reference the Primary Parent via a check box. This functionality is not replicated in PI Builder. Thus, yo...
Guest over 3 years ago in AVEVA™ PI Server / PI Builder 0 No status

Change behavior to retrieve contacts in bulk

In a large scale deployment, or in an undersized system retrieving AF Contacts, or accessing the subscription tab on a Notification Rule can be slow. A solution is of course to properly size the system or reduce the scale, however there is a compo...
Guest over 3 years ago in AVEVA™ PI Server / PI Builder 1 No status

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Suppress the creation of "Status Flag" PI Points

The end-user would like to suppress the creation of the "Status Flag" PI Points, as they wish to keep their point count to a minimum due to the license-enforced point limit.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Add Check In / Check Out button to PI Builder

It would be useful to add a Check In and Check Out button to PI Builder. So if any undesired change is made, it can be undone.
Eduardo Mirra Galante Miller about 2 years ago in AVEVA™ PI Server / PI Builder 0 No status

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Provide PI Builder Functionality In A Google Sheets Add-on

A significant number of companies are moving from the Microsoft Office suite to "G Suite" (Google). This move takes customers from MS Excel to Google Sheets, and they would like to retain PI Builder as a functional add-on.
Guest over 3 years ago in AVEVA™ PI Server / PI Builder 0 No status

Log device information when the Connector receives errors from a device

Currently the Connector logs when it receives errors, but does not print information that can be used to determine which device is reporting the errors. We currently need to perform a wireshark trace to look at the individual packets to determine...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Distribute-Broadcast-To-Network broadcast for Discovery Tool and Connector

When running the discovery tool from a subnet with no BBMD to query BACnet devices on a separate subnet, it seems like the auto discovery tool is seen as a ‘foreign device’, so the devices do not respond correctly. When analyzing a Wireshark trac...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status