Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 76 of 5194

Outputs at close available for all generation modes

‘Outputs at close’ is very powerful and flexible. It allows one to use expression analysis syntax in event frames. Unfortunately, it is only available for generation mode 'explicit trigger', but not for 'pulse', 'step', or 'step continuous'. If y...
MarkusKoschorreck over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Additional documentation and examples to reference non-primary referenced Elements on Event Frames Templates

Some users asked for an enhancement of the documentation/ guide videos regarding syntax for referencing a non-primary element on a PI Point attribute from Event frame templates. The OSIsoft live guide does not provide enough information and/or exa...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Make Acknowledged status available within Event Frame

Since we have an EventFrame() function to pull in StartTime, EndTime, and Duration from within an event Frame, it would be useful to also be able to access whether or not the event frame was acknowledged. Use case: If level 1 users have not ackno...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 Declined

PI EFGen interface : allow configuration of events without OS-admin rights

PI EFgen interface is built in such a way that it is not possible to configure events without Windows-Admin rights on the machine hosting the interface. This is not relevant in term of security and we would like to let key-users configure events w...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

BACnet SC/SuperConnect Support

Support for the BACnet SC/SuperConnect protocol for the PI Adapter, PI Connector, or PI Interface.
Connor Hawkins almost 2 years ago in PI Connectors / PI Connector for BACnet 4 No status

trend log objects (BACnet object type 20) available from the connector

BACnet trendlog object present the opportunity to buffer at the edge where the data is collected and to gracefully recover from comms outages if data collection has been impacted. I would suspect the trendlog object could be handled similarly to ...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Parametrize the "True for x minutes" parameter in event frame analysis

It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Gregory Malek about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Allow to automatically purge Event Frame History

It is currently possible to purge Event Frames using afdiag. I know that version 2018 will bring more filters on that features. It would be nice to be able to configure the purge feature directly from PSE, thus avoiding to have the management of W...
jerome.boudon over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 Declined

Purge EFs using AFDIAG and more search criterias'

You should be able to urge EFs using more complex search criterias' than the ones provide in the latest PI Server 2018 SP3 (StartTime, EndTIme, EF Template). Most important criteria would be EF categories, but also some honorable mentions: 1. EF ...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status