To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 81 of 5194

Switch for using Name of AF Attributes from Browsable Name or Display Name

Add a Switch to the OPC UA Connector that we can choose if we want the AF Attributes to be created using "Browsable Name" or "Display Name". Using the Display Name would make it much easier for us to locate the Attribute and refer to its OPC Tag a...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

View more detailed buffer queue statistics for PI Connector for OPC UA

I would like to get a more detailed view of the buffer queue for the PI Connector for OPC UA. In particular, I would like to be able to see the number of PI Events in the queue (not just the number of Tau Messages) and the amount of space filled i...
Jaedyn Larson over 3 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Remove AF Requirement for PI Connector for OPC UA

Remove the AF requirement for PI Connector for OPC UA. Users who may only be looking to send data from PI Connector for OPC UA to Data Archive are currently forced to configure connections/security for AF as well during initial setup.
Roger Ward over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Add functionality to Pi Vision: Place to set thresholds that trigger email notifications

I have used other time series database and front ends that had the ability, while designing a screen, to also set thresholds on points and specify an email address that would get an alert email if the values were out of threshold. My company would...
dave sims about 1 year ago in AVEVA™ PI Vision™ / Notifications 0 No status

Link PI Vision error messages to source symbol on display to aid troubleshooting

When there is a dense display and an error is reported for a data source or symbol, it is difficult to find the symbol in error for further investigation. It would be useful if the error was somehow tied to the display element so that the symbol i...
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Vision™ / Notifications 0 No status

Ability to add an auto updating table of active, recent, not acknowledged PI Notifications.

No description provided
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 1 Declined

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA ...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Description

The OPC UA connector automatically creates tag descriptions when new tags are loaded (tag only mode). This behaviour may not always be desired . In our example we want to change the descriptions to something more meaningful. It would be useful to...
tdeibe01 over 3 years ago in PI Connectors / PI Connector for OPC UA 1 Evaluating

When a 'Bad' value is written to PI, store the actual Opc.Ua.StatusCode that is returned by the server in the logs

Since the actual Opc.Ua.StatusCode cannot be stored directly in the PI Point (can only use SYSTEM digital states), when a 'Bad' status code is received by the connector, the actual StatusCode should be stored in the logs (verbose or information) w...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status