Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 405 of 5219

Provide visual indication of attributes that are used as calculation inputs or outputs

it would be useful if there were a way to easily identify which attributes represent inputs to an analytic versus those which represent outputs.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add Continue() Function To Asset Analytics

Similar to the Exit() function, a Continue() function would be very helpful in reducing the calculation load on my analysis service, in this case by not fully executing variables if a condition is true. For example, if I'm evaluating the state of ...
Kelsey Bobeck over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Check history of data discovery in the OPC UA Connector for a data source

Need the option to check historical data discovery dates and times from an OPC UA Connector's data source. There is a Last Discovery performed in the DATA SOURCE TOOLS, however, we should be able to see all of the "Last Discovery" of the data source.
Adam Paranick about 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

Support Renaming Template Attributes Created by the Connector

Renaming attributes created by the connector is an unsupported modification. It would be helpful to be able to also rename the attributes created in the AF database, the same way it is possible with the tag name of the points in the DA.
Guest almost 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

New analysis to perform insert into AFTable

Hello, We have a use case that would benefit from being able to insert into an AFTable from an analysis. This would work in the same way that event frames do, where a trigger condition is meet that causes the row to be inserted. The variables from...
Trevor Flynn about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Manual recovery

Please introduce manual recovery option within OPC UA Interface because if we have to go back in time to recover data then there is no option to do a manual recovery.
Navanita over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Simpler performance analysis service statistics review directly in AF Explorer

Consider implementation performance analysis service statistics in AF Explorer which is now performed in a complicated way by exporting data to Excel, rearranging and viewing in a pivot table. It would also be useful to be able to retrieve that da...
igreguri over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Naming of the Data Access Filter File when exporting the available Type Definitions

Currently, the filename will always be AvailableTypeDefinitions.csv. The filename should contain at a minimum the data source name. For example: __AvailableTypeDefinitions.csv
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

PI Connector automatic configuration file loading

Have PI Connector for OPC UA to read automaticaly the tag configuration file (.CSV).
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Filter OPC UA variables by Data Type

When selecting data for the OPC UA connector (version 2.x), we'd like to be able to filter for variables by data type. For example, we may have a lot of variables in our OPC UA address space that have the NULL data type. It could take a lot of ove...