To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 452 of 5219

As an avid user/admin of AF, in PSE I would like an option to display large attribute values with commas

Currently, in PSE there is no way to display attribute values greater than or equal to 1000 with commas for the thousands separators. Ex: 1,234,456 instead of 123456. This option exists in other PI Clients (i.e. PI Vision) and should be available ...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 Declined

Get Description from the OPC UA Server into the AF attribute

Get Description from the OPC UA Server into the AF attribute
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 0 Declined

Prevent OPC UA Connector 2.x from doing Data Discovery in Tags-Only mode

Use case: If we are frequently adding OPC UA tags and OPC UA server has a large variable count, then each discovery will increase the amount of time for it to complete. This increases the amount of time needed to discover the data source + configu...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 Tell us more

Ability to use substitution parameters in attribute template names

Would like ability to use substitution parameters in attribute template names.  Using PI-SNMP for Linux file partition data. We need to know the storage index# in AF since they vary server to server.  Want to provide users doing searches...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

substitution parameter for point attribute

At the moment i have to conifgure attributes like description or uom in PI Tags and also in the corresponding AF attribute. it would be great if i could use substitution paramertes like point.uom or point.descriptor in PI AF to fill configure Attr...
FranzK over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Support string values in formula data references

Formula data references do not support string value type attributes (e.g. if stringattribute="Yes" then "X" else "Y"). One workaround is to create an analysis on the element template with the same logic mapped to an attribute on the element templa...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 5 Declined

Ability to change the timezone used in PI System Explorer with a feature similar to what is found in PI DataLink or PI SMT 2017.

As an end user, I would like to be able to change the timezone referenced in PI System Exporer from client timezone to server timezone. Something similar to the "PI Data Archive Time Zone"  setting found in PI DataLink would be helpful.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 8 No status

Add filters support to AF Summary calculations

PI-DataLink allows for filtering of aggregate calculations, for example to get the average inlet temperature of a compressor when the turbine speed is > 1000 RPM. This is not possible with AF. The KB01120 article does not work and is very mess...
Simon J. Dyson over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 6 No status

PI OPC UA Connector to write Bad Input/Configure

PI OPC UA Connector to write Bad Input/Configure when the respective NodeId is no longer available in OPC UA Server.
Fnu Safdar about 2 months ago in PI Connectors / PI Connector for OPC UA 0 No status

OPC UA Connector Trend Advise Option

OPC UA Connector Trend Advise Option, such as in the UniInt interfaces
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 5 No status