To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connector for OPC UA

Showing 67 of 4876

An import-export feature for PI Connector for OPC UA similar to the one used to configure OPC DA points

Having to select the OPC UA server points to import from a list with thousands of points where a naming rule is not followed is a never-ending task using the OPC UA Connector web interface. My suggestion is to create an interface similar to the on...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Add a checkbox disabling Tag and Element creation

Case1: OPC UA Connector configured in a way that if the automation system will offer new tags, they will be created on PI system automatically. However, this makes running out of tags on the PI Server. Is there a possibility to start the OPC UA Co...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 1 No status

OPC UA bi directional communication

like the PI Interface OPC DA, it would be good to have the possibility to read and write value back to the source system.
Pascal_13 8 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

Update PI Connector for OPC UA to be interoperble with OCS & EDS

Update PI Connector for OPC UA to be interoperable with Edge Data Store (EDS) and OSIsoft Cloud Services (OCS).
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Add one more option for the "Incoming Timestamps"

Add one more option for the "Incoming Timestamps" Be able to use take the timestamp direkt from connector server/PC.
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Connector should create point in PI server irrespective of the source tag value field, whether blank or null

Connector should create point in PI server irrespective of it's value status in OPC UA server side, whether the source tag value field is blank or null, in either case, PI tag should be created for PI Connector for OPC UA 2.0.
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Enhance data collection manager compatibility

At the moment also the newest version of the DCM has many issues with different browsers. Buttons will not work, lists doesn't scale right and sliders hinding. Especialy the performance leak. We have 8 datasources with 500k values and 800 tags sel...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest 7 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Manual recovery

Please introduce manual recovery option within OPC UA Interface because if we have to go back in time to recover data then there is no option to do a manual recovery.
Navanita about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status