To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow PItoPI APS connector to sync "Point Type" changes

Currently (as of PI to PI Interface AutoPointSync Connector Version 1.5.0.7), it's not possible to sync changes to "Point type". (See pg 5 of user manual). Please make this possible in a future release.
Guest almost 4 years ago in PI Interfaces / General 0 Declined

PI OPCtoCSV tool to continue running and skip branches in error

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. When the tool is run into error with certain branches, the tool will stop and disconnected from the OPC server/tunneller. For example: “GetItemProperti...
Ee Sheing Lee almost 4 years ago in PI Interfaces / General 1 Declined

Allow diagnostic tags per failover node for batch interfaces

Batch interfaces should allow for diagnostic tags per failover node, just like UniInt based interfaces. Currently, there is no differentiation between the diagnostic tags for the primary failover node versus the backup failover node. The Location3...
Guest almost 4 years ago in PI Interfaces / Batch Interfaces 0 No status

PI Interface for IEEE C37.118 support for Analog data Signed and Unsigned 16-bit Integers

The IEEE specification of the IEEE C37.118 protocol does not specify if analog data should be singed or unsigned for 16-bit integers. The currently the PI Interface for IEEE C37.118 represents these values as exclusively unsigned. Both types shoul...
Guest almost 4 years ago in PI Interfaces / Other Interfaces 0 No status

Enhance WMI interface to verify that ACE Class Libraries are running

PI-ACE Manager looks at the PI-Module Database to see if the individual modules are running. The Class Library sub-processes updates the PI-MDB when it starts & stops. If the process dies, it does not always update the PI-MDB values. So, there...
Joe Staublin almost 4 years ago in PI Interfaces / Other Interfaces 1 No status

PI BACNET interface support BACnet Intrinsic Reporting (BIR)

PI BACNET interface should support BACnet Intrinsic Reporting (BIR). It allows PI BACNET interface to subscribe alarm information. We will not miss the alarms if it will be implemented.
Kenji Hashimoto 12 months ago in PI Interfaces / Other Interfaces 0 No status

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA ...
Guest almost 4 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Description

The OPC UA connector automatically creates tag descriptions when new tags are loaded (tag only mode). This behaviour may not always be desired . In our example we want to change the descriptions to something more meaningful. It would be useful to...
tdeibe01 almost 4 years ago in PI Connectors / PI Connector for OPC UA 1 Evaluating

When a 'Bad' value is written to PI, store the actual Opc.Ua.StatusCode that is returned by the server in the logs

Since the actual Opc.Ua.StatusCode cannot be stored directly in the PI Point (can only use SYSTEM digital states), when a 'Bad' status code is received by the connector, the actual StatusCode should be stored in the logs (verbose or information) w...
Gabriel Verreault almost 4 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp almost 4 years ago in PI Connectors / PI Connector for OPC UA 1 No status