AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 173 of 5192

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Guest almost 2 years ago in AVEVA™ Adapters / General 1 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Simplify the security configuration for OPC UA

The newer OPC UA protocols have stricter security standards, which is good, but that makes configuring connections more difficult, especially with regard to the need to put in tunneling and open ports. It should be easier to establish a secure con...
Laurie Dieffenbach about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide possibility to create stream metadata from table data

Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status information ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Use the most recently used Locale as the default

The default Locale is currently "English - United States" for all new data sources. Please consider using "English - United States" as the default Locale only for the 1st data source, and using the most recently used Locale as the default for all ...
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Enable PI UFL Connector to read csv with empty data fields, eg. no value between commas

Enable UFL Connector to interpret two consecutive commas in a csv file to mean that the data field is empty. The UFL connector should interpret this empty field as a zero.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

PI UFL Connector - enable option to treat nulls values for fields as their defined data type instead of as strings

When the UFL connector sends a value that is null, it is treated as a string. As a result, any variables that are defined as other data types (other types as listed here https://docs.osisoft.com/bundle/pi-connector-for-ufl/page/field-section-state...
Paul Kim over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status