Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 22 of 5194

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect
AlexMeade almost 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Add option to select interface behavior for bad timestamps (PI RDBMS)

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the interface attempts to use the current timestamp instead and logs the following error: "pitm_settime() error - 15002. Using current...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Accept weeks and years in the relative time syntax for history recovery start and end times

For whatever reason, times such as *-1w or *-1y are not accepted, but times such as *-1mo and *-1d are OK. Please make the PI Interface for RDBMS accept the same relative times that other PI programs accept.
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS Interface - Full Sync and Annotations

The PI SDK writes required for setting annotation values with the exdesc and RDBMS interface are not compatible with Full Synchronization. Make this compatible.
Matt Voll over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

New start-up parameter /SYNC_TIME defining a floating-window during which the interface will keep a RDB table in sync with PI data archive

The new RDBMSPI param:  /SYNC_TIME=rel_start_time,rel_end_time   for instance /SYNC_TIME=*-6h,*+1h When set, the interface: - after each execution of a query, which shall have the same "floating" window in its WHERE clause; for insta...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 1 No status

Accept the dd-mmm-yyyy format in the absolute time syntax for history recovery start and end times

The PI Interface for RDBMS currently accepts the format dd-mmm-yy but not the format dd-mmm-yyyy for history recovery start and end times. The former format lacks the century, so the year is ambiguous. The latter format solves this problem and so...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status