To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 659 of 5259

Install and configure more than one PI Connector Relay instance per server

At local industrial sites, we deploy use cases different in nature and end user consumption in separated AF DBs, like OEE, PSM, Autoclave, utilities, etc. We need to centralize these individually into our central PI System. We need to segregate th...
Christian Leroux over 3 years ago in PI Connectors / Installation 0 No status

Disable Highlight on selected object

Customer wants to disable highlight on selected object in Table
Guest 8 months ago in AVEVA™ PI Vision™ / Authoring Displays 0 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Ee Sheing Lee 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

Include MSXML with the latest version of the PI Interface for OPC XML-DA

The Read-Only version of the PI Interface for OPC XML-DA (1.7.3.40) does not contain the msxml4 library necessary for communicating with the OPC XML-DA. The workaround is to install the Read-Write version of the interface and then the Read-Only ve...
Randy Giguere about 1 year ago in PI Interfaces / Other Interfaces 1 No status

Support user-defined data types in the PI Connector for EtherNet/IP

As an advanced user, I would like to be able to specify a user-defined data type for the array sent to the PI Connector for EtherNet/IP.  For example, if I have a 32-bit array composed of one INT and two SINTs, I would like to be able to conf...
Guest over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Synchronize behavior between PI Connector for Cygnet and Cygnet enumeration value representation

The values stored in the “Table Entry” column in Cygnet TRS should match the “State” column in the PI Server Digital states table. This way end users are not confused why the trends in PI do not match the trends in Cygnet.
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Allow rename of tags for IEC-60870-104 connector

The connector should allow sending the data to a custom tag name. The combination of ASDU and IOA are not useful to end users without the signal list. There should also be an option to automatically combine the quality flags with the value e.g. i...
sahilp over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Further development of OMF

In OMF unfortunately more complex use cases are not possible Integration of Script functionally for generated elements from OMF are needed. Please insert an possibility or allow an other development method to use all AF functionality in case of ge...
photi24 over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Remove AF Requirement for PI Connector for OPC UA

Remove the AF requirement for PI Connector for OPC UA. Users who may only be looking to send data from PI Connector for OPC UA to Data Archive are currently forced to configure connections/security for AF as well during initial setup.
Roger Ward over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Exclude Bad values from data collection in PI Connectors

PI connectors such as OPC UA, Wonderware and Cygnet send BAD values from the data source. We would like the option to filter these values out at the connector level such that they do not make the PI Data Archive.
Guest over 3 years ago in PI Connectors / General 0 No status