Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 332 of 5259

PI to Connect Agent instance Failover

on behalf of customer: We would like to see agent failover added to PI to Connect. The PI System already provides high availability, and extending this capability into PI to Connect would deliver a resilient hybrid infrastructure end-to-end. Histo...
omar alomari 4 months ago in PI to CONNECT / General 1 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 16 Planned

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Interface for Performance Monitor - Parameter to Ignore Device Status for Failover Pairs

When machines being monitored by the Performance Monitor Interface go offline, PerfMon Interfaces in failover pairs can thrash due to the health point device status for the machines not being resolved after a failover event. (The machine is still ...
Joshua Weishaar about 1 month ago in PI Interfaces / Other Interfaces 0 No status

Automated discovery on a schedule

Enable Regular Discovery: While not continuous by default, discovery can be scripted or scheduled to run periodically for dynamic environments include this as a feature, so that automatic discovery and automatic addition of new discoveries can be ...
Nick Ciampa about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Root Element should be added to the transfer

When we create a transfer from PI AF there is a way to select a Root Element to start the search. However the root element from where we start the search is not added to the transfer. Ideally we would be able to add the root element into the trans...
Fabio Dani 3 months ago in PI to CONNECT / General 0 No status

Allow Multiple Data Archives per PI to CONNECT Agent

Allowing data transfer for tags from multiple PI Data Archives with one agent will help to cut down on the number of agent services, and therefore machines, that need to be involved to send data from PI to CONNECT.
Guest over 3 years ago in PI to CONNECT 0 In development

Add SOAP 1.2 support to the PI Interface for OPC XML-DA

The current version of the PI Interface for OPC XML-DA seems to only support SOAP 1.1. All recent OPC XML-DA servers are developed following SOAP 1.2 standards, meaning the PI interface will not connect. Please enhance the interface to also suppor...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status