Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 495 of 5258

Update the CA ISO interface in preparation for the upcoming API V8 deployment

CA ISO is planning to upgrade its ADS (automated dispatch system) to version 8. This upgrade introduces breaking changes from the current system, API version 7. The CA ISO interface should be updated to account for these changes.
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Vision Page Authoring Tools Improvement

I noticed quite a number of issues while attempting to author a new PI Vision Page. Here are a list of things that are lacking in PI Vision compared to PI ProcessBook and needs to be included into PI Vision as soon as possible: 1. Unable to Copy a...
MUTHULINGAM RAMIAH over 3 years ago in AVEVA™ PI Vision™ / Authoring Displays 0 No status

Annotations support in PItoPI

Annotations are crucial in some instances. PItoPI should be able to handle annotation duplication.
Alan Izar over 3 years ago in PI Interfaces / PI to PI Interface 3 No status

UFL Interface - Increase UFL designer sample data file size limit beyond 50 KB

The UFL designer currently limits the sample data file size to 50 KB. This requires users to truncate their text files until it is below this limit.
Paul Kim over 3 years ago in PI Interfaces / PI Interface for UFL 1 No status

EFGEN - Allow Zeroth State strings to be used with Digital-type Active Points

When my EFGen Active Point tags have a type of digital, the interface should allow certain digital states to be designated as a Zeroth State.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

PI Interface for SNMP accounting for Dynamic OIDs

Certain MIB files use dynamic indices which make dynamic OIDs. As the interface uses OIDs in the instrument tag manual action is needed to repair it should the OID change. This is particularly prevalent when using the HOST-RESOURCES-MIB, which use...
Guest over 3 years ago in PI Interfaces / Other Interfaces 3 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more