To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 133 of 5194

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI BACNET interface support BACnet Intrinsic Reporting (BIR)

PI BACNET interface should support BACnet Intrinsic Reporting (BIR). It allows PI BACNET interface to subscribe alarm information. We will not miss the alarms if it will be implemented.
Kenji Hashimoto 4 months ago in PI Interfaces / Other Interfaces 0 No status

OPC Alarms&Events interface should natively support event frame creation

As a PI Interface for OPC Alarms & Events user that would like to leverage AF Event Frames for more advanced analysis, I would like for the OPC AE interface to have an option to natively create event frames that open when a Status = Active mes...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Store bad quality from OPC XML DA Server

Enhance the OPC XML DA Interface to store bad quality values from its OPC XML DA Server in PI, so that the values, timestamp and status from bad quality data are saved in PI. Note: This is work item 21742OSI8 - Add support of data quality.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Encrypt trafic between interfaces/connectors and the Data Archive

Add an option to encrypt trafic between interfaces/connectors and the PI Data Archive
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Update the CA ISO interface in preparation for the upcoming API V8 deployment

CA ISO is planning to upgrade its ADS (automated dispatch system) to version 8. This upgrade introduces breaking changes from the current system, API version 7. The CA ISO interface should be updated to account for these changes.
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status