Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA Adapter for OPC UA

Showing 26 of 4924

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

PI Adapter for OPC UA Discovery file attributes setting

At the moment the file generated consists 5 columns - nodeId,selected,name,streamId,dataFilterId. Columns "name" and "dataFilterId" are always with value "NONE". There is no option to set the attributes to include in the file.
Ivan Lozanov 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration