Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 71 of 5192

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Automatic sending of historical data (backfill) after communication

Be able to backfill data for a significant amount of time if there is a undetected or temporary uncorrectable network failure.
Guest over 3 years ago in PI Cloud Connect 1 No status

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Extend the history recovery max period for PI Cloud Connect to longer than 30 days

Allow history recovery for PI Cloud Connect to be longer than the current max of 30 days
Guest over 3 years ago in PI Cloud Connect 1 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Cloud Connect should be able to write to more than one Data Archive

I am a subscriber who receives data from multiple organizations in different (>15) subscriptions. Due to needing the data to be located in different Data Archives as each is for a different business area, one instance of PI Cloud Connect should...
Guest over 3 years ago in PI Cloud Connect 0 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status