To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility.

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility. This should allow failover based on connectivity and/or a watchdog (like failover if a specific tag stay stale for a configurabl...
Guest almost 4 years ago in PI Interfaces / PI to PI Interface 0 No status

Allow the UFL interface to delete PI tag data or provide some other supported automated method of deleting PI data from a collective.

There is no way to easily delete data in a time range if you want the changes to occur on both the primary and secondary data archive. It seems the UFL interface would be good to use to do this. You could provide it a tag name and time range and t...
Heather Boehler almost 4 years ago in PI Interfaces / PI Interface for UFL 3 No status

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest almost 4 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

PI OPCtoCSV Tool: Filter by OPC ItemID

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch like the PI APS Connector for OPC DA interface, but unlike the APS Connector, it is not possible to fil...
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI AMI Itron Interface support for TLS1.3

PI AMI Itron Interface currently supports TLS1.1. Microsoft ended support for TLS1.1 in March 2020. To keep the PI AMI Itron Interface usable with latest browsers, please update to support TLS1.3.
Guest almost 4 years ago in PI Interfaces / Other Interfaces 0 Evaluating

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

More Database Options for PI Event Frame Generator

Allow configuration options for different databases via the PI Event Frame Generator. Being able to connect to a database via ODBC and then have a configuration file that would allow adding entries from that database as Event Frames would be very ...
Brian Rock 5 months ago in PI Interfaces / Other Interfaces 0 No status

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Joshua Weishaar 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more