To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Store Images & Pictures into EDS

Ability to store images as time bound data into EDS, and send the images to OCS for longer term storage, viewing or modeling/analysis. Example scenario: a thermal camera takes a picture of a furnace, image stored locally, and then sent to OCS whe...
Guest almost 4 years ago in Edge Data Store / Historian 2 Evaluating

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Gabriel Verreault almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest almost 4 years ago in AVEVA™ Adapters / General 0 Tell us more

Support an analogue to the "step" PI Point attribute when creating PI Points

Even though it will indeed be useful to be able to specify whether data should be retrieved in a step-wise fashion, for new PI Points (assuming you're writing data to a PI Connector), it's important to be able to specify that those tags should hav...
Guest almost 4 years ago in Developer Resources / Open Message Format (OMF) 1 In development

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 8 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 4 Tell us more

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 8 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 2 No status

The Adapter framework needs to be able to perform scaling on raw data

Many users want to use Adapters for the nre abilities they offer versus Interfaces: Support for containers, Linux, edge deployment, new failover and fault tolerance, integration with CONNECT Data Services, etc. HOWEVER, many sites use Interfaces t...
Daniel Lopez about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Future consideration

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

Publish a sample of code to do an histogram

Publish a sample of code to do an histogram with PiVision extensibility. There is already a sample using a unique value (arrow) but there should be an exemple for charts to help people customise their experience further.