To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber almost 4 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / General 4 Future consideration

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks 9 months ago in AVEVA™ Adapters / General 0 No status

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Support https instead of http only

No description provided
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / General 2 Future consideration

Store bad quality from OPC server

Enhance the OPC DA Interface to store bad quality values from his OPC Server in PI, so that the values, timestamp and status from bad quality data are saved in PI.  Note: This was previously Enhancement 114636.
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Add a parameter to disable NTLM authentication

On the "Health endpoints parameters" page of the documentation of any AVEVA Adapter, it states that Negotiate (i.e. try Kerberos first and fall back to NTLM if that fails) will be used if a username/password pair and a clientId/clientSecret pair a...
Kenneth Barber about 1 month ago in AVEVA™ Adapters / General 0 No status

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest almost 4 years ago in PI Interfaces / Batch Interfaces 2 No status

Automatic Configuration Sync between failover adapters

When adapters in a failover group, any changes to configuration need to be manually synchronised between the adapters. Without automation, this could lead to misaligned configuration causing data collection issues.
Mike Horrocks 2 months ago in AVEVA™ Adapters / General 0 No status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...