To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Analytics & Calculations

Showing 317 of 4893

Better show current analysis in template

We have a template called AnalogPVAsset with an analysis called BadValues (see attachment level 1). Derived from that template we have a template AnalogPVSTSEuLoHiAsset where we have overridden the BadValues analysis (see attachment level 2). The...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

scheduled recalculation

For our technical account we have to do recalulations on a daily basis, because of late arriving data. Auto-recalculation is not an option, because late arriving data that arrives after we have published the results, should not(!) be respected any...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Improve version control mechanism to consider also PI AF Analysis & Notifications Elements

Improve version control mechanism to consider also PI AF Analysis & Notifications Elements: Background: When adding or removing an attribute to an Element in PI AF, the element's revision number is incremented (as expected) which makes the re...
Moshe Sabag about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Sort Function for example sort values from lowest to highest vice versa in PI Analysis

Analysis
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Declined

Limit the load of the PIRecalculationprocessor when backfilling

We had a few issues with key-users creating inefficient AF Analysis and starting a backfill over a longer time period. This resulted in a CPU load of 100% (caused by the PIRecalculationprocessor). The whole PI System got not responsive incl. PI Sy...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Provide 'GoTo' like Funciton

Please provide a 'GoTo' like Funciton for Analysis Expressions to skip expressions or maybe even go back to a previous Expression. I realize you don't have line numbers per se, but if the Expressions operate in order, could you use the Variable Na...
Pete Long about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow Asset Analytics to output to annotations

As someone who has migrated our calculations from PI ACE to Asset Analytics, we need to be able to annotate various calculation outputs in the same way we were able to with PI ACE. Please enable analyses to output annotations to various PI Tags in...
Roger Ward about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Add 'Stopped by user' status for analysis

As an AF administrator, I would like to understand the difference between an analysis that is stopped by an end user, or an analysis that has stopped but should likely be running. Currently when an analysis is stopped, we do not know if this is ex...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek 6 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks 6 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status