Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Analytics & Calculations

Showing 208

Enhance functionality of NumOfChanges

By now the NumOfChanges Function in AF Analytics does not take into account the value at the start of the timerange. NumOfChanges only counts the amount of changed values of the recorded values in the given timeframe. If I query the NumOfChanges ...
juergen.b.schmidt over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Replace function to be added in AF analysis

It would be interesting to add the Replace function (like the one in StringBuilder) directly in AF Analysis
Gael over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Add reset and hold triggers to SQC analytics

Add the triggers to SQC rules to reset or hold the SQC rule. When monitoring a periodic or batch based process, a user needs to be able to hold the SQC rule or put that rule in a hold state until the process resumes. Without this feature, virtuall...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Delay Real-Time Calculations until backfill is finished.

For recursive Analyses such as below : PrevVal(tagA,'*') + 'TagB' → output : tagA When the PI Analysis Service is down (or the node needs to be restarted), the current calculation needs to be halted until the Backfilling reaches up to the start u...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

PI Point User Settings in AF Client

The Suggested PI Point Name configuration item in the AF Client should be able to be set on a AF Server basis instead of a User basis, at least as the initial default. There are default parameters we need to enforce from an enterprise/site level b...
Matt Voll over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 7 No status

Put an Asset into Offline Mode which stops related analyses and notifications

Have a way to manually (or automatically via another calculation/analytic) put the status of an asset/equipment into an offline/maintenance mode that has the effect of turning any analyses and notifications for that asset off.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Option to use Good Data only in Analyses.

Analyses can suffer from bad calculations due to bad events for a tag, such as system digital state events returned for a numerical tag. Although BadVal() can be implemented to avoid using bad events in these analyses, they add another layer of ...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Trigger Rollup Analysis Upon Adding Child Elements

It would be useful to trigger event-triggered rollup analyses upon adding new children. Currently rollup analyses are only triggered when rollup attributes are updated (and not triggered when rollup attributes are added). This would be particularl...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Provide a way to backfill/recalculate analyses from Analysis Template tab in PSE

It is difficult to find all the analyses from template to backfill/recalculate after making changes in Analysis Template.  Currently one has to navigate to the Management plug-in, do some sort of search/filter, then queue the analyses.  ...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Analysis - Remove backfilling

When a failover occur or at service startup, ALL analysis configured for backfilling executes based on the last configured backfill/recalculate timerange. There is actually no feature to manually remove a configured backfill on a specific analysis.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status