To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 450 of 5194

Enable Auto Discovery for PI Adapter for MQTT SparkplugB to always listen for Birth and Death messages

When utilizing the SparkplugB protocol for MQTT, it would be beneficial for the adapter to be always listening for birth and death messages from specific Edge of Network nodes. This way, the device can send a birth message to have itself added t...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 Tell us more

Add AVEVA Adapters to the Enterprise Agreement

Before, one of the main attractions of the Enterprise Agreement (EA) was that you get unlimited access to all standard PI Interfaces and PI Connectors. However, now that AVEVA Adapters are the successors to PI Interfaces and PI Connectors, and sin...
Kenneth Barber over 3 years ago in AVEVA™ Adapters / General 2 Declined

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Include filtering logic in asset analytics

In Asset Analytics, there isn't a way to include a filtering function in a single analytic. For example, you may be calculating run hours on a motor, but there is no way to filter the calculation so that it is only done when the motor is running.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Calling or Triggering an Analysis from another Analysis

It would be great to start an analysis from another analysis or to trigger an analysis on (successful) completion of another analysis. Nice would be to have a function like Call("AnalysisName"). Real great would be if Call() would return a retur...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

R Integration with asset analytics

Similar to this request : https://feedback.osisoft.com/forums/555148-pi-server/suggestions/17119519-matlab-integration-with-af-analytics I need to integrate R and asset analytics to execute more advanced calculations
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Which attribute triggered analysis

I have an analysis that is event-triggered by multiple attributes. This analysis has the purpose of merging input attribute events with output tag, therefore I need to know which attribute triggered analysis to save only the newest event to outpu...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add an analysis function to find the Kth largest value in an array

Expression analyses allow you to find the largest value of an attribute over a specified time range using the TagMax function. A function which offers the ability the find the Kth largest value (i.e. 2nd, 3rd, etc.) would be useful. Something simi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Enable Compression for recalculated Analyses up to "Now"

Analysis Recalculation produces Out of Order Events, which means they are not compressed. The reason for this behavior is, that there is a more recent snapshot value existing. This also happens, when Recalculation is performed till "Now" (*), beca...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more