To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Analytics & Calculations

Showing 206

Write arrays to time series pi points

When I have several similar attributes, I'd like to be able to store them as an array of values on a single pi point with the same timestamp. For example: I'm rolling up values for 10 different teams. I currently need 10 rollup analyses, 10 attrib...
Jason Novotny almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Rollup through entire hierarchy

I'd like the ability to roll up attribute values through the entire hierarchy - evaluate ALL sub elements down to the lowest level, not just the direct child elements.
Jason Novotny almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Insert new row at any position in the analysis

New rows are always added to the bottom of an analysis. If they are needed near the top and many rows already exist, moving them up one at a time can be extremely time consuming and tedious. I'd like to be able to add a new row between any two exi...
Jason Novotny almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Permit me to keep "no data" and also use tag with AF Analytics

I'd like a way that permits me to use AF analytics on "no-data" pi points without requiring me to strip/remove all no-data points, so that I can also use "no-data" for notifications.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Button for unchecking all Trigger On attributes when setting up an analysis

When setting up an Analysis in Pi System Explorer as Event Triggered, all attributes will by default be chosen as Trigger on. Normally, I would only like the analysis to trigger on one input, if there are many attributes deselecting all is time c...
Haavard over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Automatic recalculation on template based analysis without automatic recalculation

It should be possible to check "Recalculate analysis for out-of-order input events" if the analysis is based on a template and the re-calculation is not checked in the template. A change of the output time stamps is already possible.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Trigger analysis on events since time creation of new version AF element.

Situation: Attribute of an AF element is one of the triggers for Event Frame analysis for sending critial Notifications. Currently: After creating a new version of an AF Element and setting a new value for the attribute the changed value will poss...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Increase the discoverability of the windows that are accessible by right-clicking on the Operations pane

In PI System Explorer → Management, with the Analysis radio button selected, right-clicking in the Operations pane gives the user access to additional windows. Even though this is documented, it is not very discoverable. Users do not expect right-...
Kenneth Barber over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

close/open event frames based on events, not transitions

I use analysis to toggle a boolean or integer from 0 to 1. This is used as source to close/open event frames (step continious mode). this is working fine in real-time. But when I do a recalculation for a part of time in the past (not until *) on t...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

split analysis is real-time and recalculation part (different logic to be used)

It would be nice if we could have a "real-time" and "recalculate" part in an analysis. As source data could have changed you probably want sometimes the analysis to act in another way. Example: 2 attributes are used to trigger an event-triggered a...