Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 2210 of 5258

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI Manual Logger Web でのエラー境界線のカスタマイズ

グリッド ビューでは、オペレーターは制限列の薄い黄色のエラー境界線を確認するのが困難です。何かが制限違反であることを簡単に確認できるように、エラー境界線の太さと色をカスタマイズする方法を希望します。
Guest almost 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

PI マニュアル ロガーWebのツアー スケジュール設定

PI Manual Logger PC では、スケジュールに従ってツアーを実行するように設定できます。これにより、アプリケーションがツアーを最も近い時間で実行するのではなく、ツアーの実行時間を設定することができます。 PI Manual Logger Web では、ツアー スケジュール設定は考慮されません。定期的なツアー スケジュールに従って、PI Manual Logger Web にツアー実行の機能を追加を希望します。
Guest almost 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add a performance counter which can measure if Event frame reconciliation is performed correctly

Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis on roll up

We should be able to perform analysis or at least data filter at roll up. e.g. roll up attriubutes A while Attribute B > 5
Kareema Ramli over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow to set individual min-max when in multiscale on trend symbol

In Pi Processbook, it was possible to adjust the min/max for each tag even in multiscale mode. In PI Vision, it is not possible and our users require it.
jerome.boudon over 2 years ago in AVEVA™ PI Vision™ / Symbols 2 Already exists

Define time for analysis "evaluate" button to make debugging faster

Currently, the evaluate button can run your evaluation at the current timestamp and the last scheduled time. It would be really helpful to key in a 3rd timestamp to diagnose edge cases. The current workaround involves putting dummy variables in to...
RyanCarpenterAd over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Give a warning or more descriptive error message when trying to recalculate when output point has relative time set

Recalculation doesn't work when Relative time is set on the output point. Currently the error given is the one shown in Unable to manually backfill analysis from PI System Explorer: One or more output attributes do not support recalculation. Which...