Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Expose triggering input to Analytics

If an analysis with multiple trigger attributes is triggerred, it is difficult to assess which attribute produced the trigger. Hasvaluechanged has it's limitations, and comparing PrevEvent is also cumbersome. Instead of only receiving a timestamp...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

New functions for analysis

New functions are needed for most problems in our fileds process and quality: * countif (count with conditions over specified horizon) * for loop (even it might be hard to implementate)
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

Make badval() in Formula data reference equivalent to BadVal() in Analytics

Currently, BadVal() in Asset Analytics can handle situations like BadVal(1/0) without throwing a divide by zero error, but the badval() function in the Formula DR cannot. The request is to make them equivalent so that behavior is consistent across...
Brent Bregenzer almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

Preview Results should display values of variables in event frame generation analysis

If I want to create an analysis that generates an event frame in PI System Explorer, often times it's useful to check the values of variables to make sure that a calculation is being done as expected to mitigate error on my end, and make sure I am...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis tab can be slow to load

The analysis tab in PSE can take quite some time to load if there are thousands of elements being referenced in the input attributes. This is rare for Expression, Event Frame and SQC analyses, but not as rare for Rollups. Ideally the tab should lo...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Upgrade the PI Interface Configuration Utility to a responsive web-based user interface

OSIsoft's migration from PI Interfaces to PI Connectors is very slow. Even after the migration is complete, many PI Interfaces will not be upgraded to PI Connectors, so users will continue to use the PI Interfaces and the PI ICU to configure them....
Kenneth Barber almost 4 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Allow PI-ICU to Create/Edit Stored Credentials in Credential Manager

An issue we run into often is that most of the accounts that are used to run our interfaces (mostly OPC DA) are different from accounts we use to configure the interfaces. Because these interfaces run on different domains, we have to store an acco...
Brian Rock almost 4 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 4 No status

Support Automatic Failover for PI UFL

Currently UFL only supports two independent instances for redundancy purposes.
Guest almost 4 years ago in PI Interfaces / PI Interface for UFL 0 Declined

AutoPointSync for OPC DA should work on 64bit servers.

AutoPointSync for OPC DA does not install or run correctly on 64bit servers. As most new servers are 64bit this would seem to be an essential capability.
zubzub almost 4 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

change the default behavior of the OPC DA interface to use /DC

per the OPC DA 2.x spec, the OPC server will call us back for all points that have a changes; even those points where we are polling. We have a switch to disable the callbacks for points that are not set to advise: /DC Can we make that the defau...
Clint Ramsey almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status