Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Analytics & Calculations

Showing 318

PSE Analysis Preview Results to indicate the origin of the event times

In PI System Explorer, when using the Preview Results function for analyses, I want the dialog to indicate which of the input attributes the current timestamp originates from. Example: Two inputs with update frequency 1 min, Input1 without offset...
Asle Frantzen about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Trilinear Interpolation

The ability to utilize three columns as input for interpolation from an AF Lookup Table to determine the result for a fourth column could be beneficial for predictions and analysis. Currently, only linear and bilinear interpolation is possible fr...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Function to extract Data Reference Type

We would like to be able to extract the data reference type (PI Point, None, Formula, Table Lookup, etc.) for an attribute using PI Analysis, similar to the TagType function for PI points.
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Improve usability of TagNum function

The TagNum function seems to be the only function that requires a double quote as opposed to single quotes. Many other TagXXX functions call for single quotes for its attribute or PI Point arguments.
Jinmo Yi about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Thorough Analysis service message logs

Having more thorough and detailed messages for the Analysis service in the event logs, especially upon startup. Environment details + Language settings that the Analysis service is using should be mentioned in the startup logs in order to better ...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow Analysis timestamp override feature to output milliseconds

When using an analysis variable as the output timestamp, it appears that the actual output timestamp is floored to the nearest second, shaving off any millisecond count. This is not a huge priority on our end, but I wanted to ask in case it was a ...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove tag need for Exit() and NoOutput() in analysis

Allow analysis outputting to Analysis Data Reference attributes to make use of the functions Exit() and NoOutput(), instead of requiring only PI Point Data Reference attributes.
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis on roll up

We should be able to perform analysis or at least data filter at roll up. e.g. roll up attriubutes A while Attribute B > 5
Kareema Ramli about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Define time for analysis "evaluate" button to make debugging faster

Currently, the evaluate button can run your evaluation at the current timestamp and the last scheduled time. It would be really helpful to key in a 3rd timestamp to diagnose edge cases. The current workaround involves putting dummy variables in to...
RyanCarpenterAd over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Give a warning or more descriptive error message when trying to recalculate when output point has relative time set

Recalculation doesn't work when Relative time is set on the output point. Currently the error given is the one shown in Unable to manually backfill analysis from PI System Explorer: One or more output attributes do not support recalculation. Which...
Guest over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status