To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Is there a way of enabling a confirmation window when modifying AF attributes or PI Points?

Suggestion:Would it be possible, in AF revisions and even in tag revisions via PI-SMT, to have a window open whenever any change is made, requesting the reason for the change? And would this information be stored somewhere with the attribute path,...
Ana Izzi 9 months ago in Developer Resources / General 0 No status

Support for the Galileosky Protocol

Need an option for direct integration of Galileosky GPS tracking devices with the AVEVA PI System without third-party middleware. The devices primarily use the proprietary Galileosky binary protocol (TCP-based, port 20332 by default) for real-time...
Mohammed Qasim Asghar 9 months ago in AVEVA™ Adapters / New Connectivity 0 No status

Reduce number of "Failure to Resolve 1 PI Point referenced by AF" errors logged in the event viewer

If there are multiple PI Points that cannot be resolved, these messages can quickly fill up the logs. Since event viewer only keeps so many messages by default, this can quickly overwrite other messages and result in a loss of information for trou...
Jessica Rammo about 2 years ago in PI to CONNECT / General 0 No status

Improve throughput

I am not sure if this is a limitation connected to the OMF, WebAPI, or https itself, but in the manual it is given that the maximum message size is 192KB. I am aware that compression is recommended and applied by default by the adapters. For the r...
sahilp about 3 years ago in Developer Resources / Open Message Format (OMF) 0 No status

Add Function to Determine if a Bit is Active in a Word Value

It would be extremely helpful if a function existed within PI AF where could provided a value/tag reference and a bit number to check and see if its active. The function would return a True or False value if that bit is active. Something like the ...
Justin Jackson 9 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks about 3 years ago in AVEVA™ Adapters / General 1 No status

Create a TriggeredOn() function for PI Analysis

The TriggeredOn() function would return true if the inserted attribute was the reason for the expression analysis to trigger/evaluate. I have multiple attributes in the same analysis but only want each line to have an output when its corresponding...
Ian Morgenstern over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Update PI Vision Extensibility Guide to include Time Range Manipulations

With the introduction of the timeseries table and the ability to add a custom time range to trends, it would be very helpful if the GitHub references were updated to include guidance on how to similarly access this and make use of the new function...
Kelsey Bobeck 10 months ago in Developer Resources / Help / Documentation / Videos 0 No status

Add database filter on AFAnalysisService.QueryRuntimeInformation

Hello, Could it be possible to add a dedicated filter on dataabse for the method AFAnalysisService.QueryRuntimeInformation? Indeed, on large systems, the PI Analysis service timeout because the call is not enough efficient. In fact, the only way t...
Gael over 2 years ago in Developer Resources / General 0 No status

troubleshooting AF Analytics with better diagnostics

I'd like better diagnostic information around why event frames are not create by AF Analytics so that my solutions are of high quality and my users have confidence in their EF data.
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status