To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 663 of 5194

Create 'Close Event Frame delay' setting

When you create PI Point Data Reference attributes in event frame templates that are used by PI Batch Interfaces, the PI Batch Interface will be responsible for resolving and capturing this PI Point data as soon as it closes the corresponding even...
Rafael Batista 10 months ago in PI Interfaces / Batch Interfaces 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks 10 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

User should be able to select multiple checkboxes in the backfilling / recalculation status. window.

Please refer the screenshot of existing window. There is no option to select multiple checkboxes. If user want to cancel multiple backfilling process which are queued (it was more than 50), then the cancellation option is not available to stop thi...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

WIS support for TCP Response interface

If trusts are disabled in Data Archive, the TCP Response Interface will generate a logon error every time it performs a TCP request (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000032778). The interface should be updated, ...
mose almost 2 years ago in PI Interfaces / Other Interfaces 0 Evaluating

Analyzes are automatically switched off by the PI Analysis Service

In the case, that the PI AF Analysis Service is overloaded, there should be the possibility that faulty analyzes are automatically switched off by the PI Analysis Service. This ensures that all other analyzes functioning correctly. The failed anal...
Marcel Rieß almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Performance Tab "Jump to" Option

When trying to troubleshoot analyses and templates that may be causing poor performance on the "Management\Performance" tab, it can be tedious to locate the selected element to start determining why it's building in error count or taking a long ti...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Quadratic Regression

Add a quadratic regression function similar to "LinRegr". This would be helpful for trending relationships that are not linear, such as flow vs. pressure.
Guest about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status