To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Add Continue() Function To Asset Analytics

Similar to the Exit() function, a Continue() function would be very helpful in reducing the calculation load on my analysis service, in this case by not fully executing variables if a condition is true. For example, if I'm evaluating the state of ...
Kelsey Bobeck almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Julian Weber about 3 years ago in PI to CONNECT / General 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Quadratic Regression

Add a quadratic regression function similar to "LinRegr". This would be helpful for trending relationships that are not linear, such as flow vs. pressure.
Guest over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis timerule option: Add a possibility to make the timerule conservative. Emit calculation events only if the snapshot time of all inputs are more recent than the planned calculation time.

Now the TimeRules Natural and Periodic emit events to the Data PIPE in case NATURAL: an event is received by one of the selected inputs case PERIOD: when a certain timespan elapse.Both method doesn't take into account that some input of the analys...
Marco Blokdijk over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status