Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 730 of 5194

PI Connector for IEC 60870-5-104 writes 'No Data' or another SYSTEM digital state when connection to the Data Source is lost.

This connector is specially used to monitor the connection of the machines, but if there is a general network crash, and the connector losses the connection to the Datasource, it will stop sending data instead of sending something to alert of the ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

Compare timestamps and output most recent value in child elements to parent element

From a varying number of child elements (all sharing the same template), I want to find the most recent timestamp of a same template-based attribute, and output the value with timestamp to an attribute in the parent element. In addition, constantl...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add To, CC and BCC for Notifications

Thanks for implementing https://feedback.osisoft.com/forums/555148-pi-server/suggestions/32874406-notification-e-mail-delivery-channel-to-accept-mul I would like to see "CC" and "BCC" in addition to "To". At out company the receipients of "To" s...
HolgerJoistOmv over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Enable or Disable single DataSource

When a datasource is actually offline and we don't want the UFL connector to keep trying uploading or connecting to it and pollute the message log . The best option would be having the stop/start enable/disable and restart options for each dataso...
Andy over 3 years ago in PI Connectors / PI Connector for UFL 3 Declined

Add a PI Analysis Service performance counter to track stopped analyses

The PI Analysis Service has performance counters to track the number of running analyses and the number of suspended analyses, but there is not one that tracks the number of stopped analyses. Currently, the only way to monitor how many AF analyses...
Bethany Jewett 8 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Matlab Integration with AF Analytics

Integrate matlab and AF Analytics so that scheduling of an analytic can be configured in PI to trigger calculations and other analyses being executed within Matlab (and written back to PI).
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 Declined

% good property of rollup analyses

As a user, I would like to configure my rollups to display a value only if the quality of my inputs reaches a minimum % good (configurable). Currently, it's not clear which inputs are used in the rollup calculation- even if some inputs have bad va...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Allow Max Rollup to provide AF Element-attribute

Using the Max Rollup function - I would like to know which element provided the maximum value and output this as well so I can historize the information.
MAMEDINA over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

Allow EventFrame("Duration") to be used as an EndTrigger

I want to stop my Event Frame after an amount of time that is stored in an AF Attribute. For my use case, the amount of time from the beginning of an Event Fame is an end triggering condition. One way to do this, would be to allow the EventFrame("...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

UFL Timezone Conversion

Supported timestamps are currently limited to Local or UTC timezones. Data sources may not be configurable to provide timestamps in supported formats. There currently exists no robust or simple way of converting between timezones using the UFL...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 5 Declined