To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Analytics & Calculations

Showing 206

User-defined functions

Allow arguments/parameters to be passed to variable definitions, effectively creating user-defined functions. For example, suppose that I want to define the function TagSum, which adds the values at all events in a time range. Then: TagSum(tag, s...
Kenneth Barber over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Totalizer that resets to 0 with Asset based Analytics

I need to calculate a running sum (totalizer) of a PI Point and reset it to 0 at the beginning of each month. I would like to do this with Asset based Analytics. There are workarounds to do this, but none are great. For example, one workaround inv...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

PI Tag Renaming Detection for PI Vision/PE Calculations

When input PI Tags are referenced in PI Vision 2020+ calculations, they do not automatically detect PI Tag name changes. For users with a lot of calculations, this can be extremely problematic in the event of a PI Tag name change. In the event of ...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

As an administrator, I would like to be able to backfill data that crosses over a versioning event

Use case: 1. An element has an attribute that looks up information on equipment configuration (ex: a pump rate) 2.  Due to an equipment change, the lookup table and the element were increased in version 3. A backfill needed to be performed o...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Better search criteria in Management tab of PI System Explorer

PI System Explorer Management Tab should have better search criteria. For example, select specific elements in which to rerun an Analysis. Maybe use Element = something OR/AND Element = something else. Or search by element path.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Allow Asset Analytics to Evaluate functions for questionable flagged values

Data can be flagged as questionable, which should mean the value may or may not be valid. Asset Analytics seems to be rejecting the value as Bad. The function instead should evaluate the result, but flagging the result as questionable as well.
Nathan Skitt over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Asset Analytics should have a performance counter to indicate data loss on the UpdateManager queue

Currently there is no way to know if Analytics missed important updates (e.g. start of a batch) without analyzing the message logs. However, the AFSDK does provide an indication on the DataPipe if the pipe is in an overflow state, allowing for a c...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Rollup Analysis of Booleans

I would like to be able to do a Rollup Analysis of Booleans attributes, without casting or converting the boolean. As Rollup Functions I would suggest: Logical AND, Logical OR and maybe Count of True/False. It can be use to create a Combined Stat...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Enable Compression for recalculated Analyses up to "Now"

Analysis Recalculation produces Out of Order Events, which means they are not compressed. The reason for this behavior is, that there is a more recent snapshot value existing. This also happens, when Recalculation is performed till "Now" (*), beca...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

Give analyses format function the ability to format timestamp

Give analyses format function the ability to format timestamp similar to the one in the formula data reference. e.g. Format (datetime, "dd-MMM-yyyy HH: mm: ss");
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status