To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Improve Data Cache Performance by parallelizing Data Archive update fetches

Currently, when the Data Cache is signed up for updates on multiple data archives, updates from each archive are fetched in series, one after another. When there are many data archives involved (especially if they are geographically dispersed) thi...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Allow approval groups in RtReports to approve in any order (parallel approvals) instead of requiring a sequential approval hierarchy.

Currently, RtReports processes approval groups sequentially. For example, if a report requires approvals from both Group 1 and Group 2, Group 1 must complete its approval before Group 2 is able to review and approve the report. The option to confi...
Guest 27 days ago in AVEVA™ RtReports / General 0 No status

PI Adaptor for Perfmon

To move to next gen AVEVA tech, and perform a migration to Adaptors, critical monitoring with perfmon adaptor (Instead of Interface for PIPerfMon) would be ideal. Portability of using linux, docker etc. and having this data be available in AVEVA D...
Nick Ciampa 4 months ago in AVEVA™ Adapters / New Connectivity 1 No status

Enlarge area for editing analysis expressions

When editing an Analysis Expression, only 4.5 lines appear. It would helpful if more lines appeared (greater than 20 lines).
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / General 4 Future consideration

Selectable Write Mode for Analyses

As an analysis user I would like to define what should happen if multiple triggers occur with the same timestamp. Currently AF analysis are using "Replace" mode when writing to the archive (meaning if multiple triggers have the same timestamp, the...
phsutter almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 7 No status

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Dennis Fendel about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Which tags are being used by a PI Analysis

As a PI Administrator, I want to know which tags are being used at which PI Analysis so I can know exactly if there is already another Analysis writing to a tag and avoid duplicated or wrong data.
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 11 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 17 Planned