To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 161 of 5194

Event Frame Re-capture/Backfill Option to Save Annotations/Reasons

When a backfill or "recapture events" option is selected for Event Frames, give the user an option to "Save Annotations" for that specific event frame. Right now, we use Event Frames to copy in Reason Codes and Comments (that are logged as annotat...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Outputs at close available for all generation modes

‘Outputs at close’ is very powerful and flexible. It allows one to use expression analysis syntax in event frames. Unfortunately, it is only available for generation mode 'explicit trigger', but not for 'pulse', 'step', or 'step continuous'. If y...
MarkusKoschorreck over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Include MSXML with the latest version of the PI Interface for OPC XML-DA

The Read-Only version of the PI Interface for OPC XML-DA (1.7.3.40) does not contain the msxml4 library necessary for communicating with the OPC XML-DA. The workaround is to install the Read-Write version of the interface and then the Read-Only ve...
Randy Giguere 11 months ago in PI Interfaces / Other Interfaces 1 No status

Additional documentation and examples to reference non-primary referenced Elements on Event Frames Templates

Some users asked for an enhancement of the documentation/ guide videos regarding syntax for referencing a non-primary element on a PI Point attribute from Event frame templates. The OSIsoft live guide does not provide enough information and/or exa...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Make Acknowledged status available within Event Frame

Since we have an EventFrame() function to pull in StartTime, EndTime, and Duration from within an event Frame, it would be useful to also be able to access whether or not the event frame was acknowledged. Use case: If level 1 users have not ackno...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 Declined

PI EFGen interface : allow configuration of events without OS-admin rights

PI EFgen interface is built in such a way that it is not possible to configure events without Windows-Admin rights on the machine hosting the interface. This is not relevant in term of security and we would like to let key-users configure events w...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

PI BACnet interface: add support for BACnet Setpoint object

Add support for BACnet Setpoint objects in the PI BACnet interface.
Kenneth Reiss over 3 years ago in PI Interfaces / Other Interfaces 1 No status

Update GE iFix interface compatibility information

As an interfaces user, I would like to know which versions of iFIX and Windows Server OS are compatible with the PI Interface for GE iFix so that I can determine whether this interface is suitable for my use case. The last update for this interfa...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 No status

PI Interface for Ramp Soak Simulator Data - Update Time Period To Seconds

To simulate data using the PI Interface for Ramp Soak Simulator Data, the ExDesc of the PI Point needs to be of the format: (period, end_value) period is the time in minutes. end_value is the value for the tag at the end of the phase period. Cur...
Mohammed Qasim Asghar 8 months ago in PI Interfaces / Other Interfaces 0 No status

PI Interface for IEEE C37.118 support for Analog data Signed and Unsigned 16-bit Integers

The IEEE specification of the IEEE C37.118 protocol does not specify if analog data should be singed or unsigned for 16-bit integers. The currently the PI Interface for IEEE C37.118 represents these values as exclusively unsigned. Both types shoul...