Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 161 of 5194

Event Frame Start and End Timestamp relative to trigger

With an event frame analysis I search for production downtimes that are longer than 30 min with the "true for" option or a "TimeGE" function. But in this way I allway loose these 30 min at the beginning of my downtime event. So I would like to be ...
JanWortmann over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Output Acknowledging Event Frame to PI Tags

AF/EF is used to contextualize the OEE Event. However, because reason codes entries does not include the name of the person who entered the code and/or the time it was entered, we leverage ODBC to gain access to the Event Frame record. Due to th...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Set Reason for closed Event Frames when it is PI Point Data Reference through PI Vision

Currently, when the Reason of an Event Frame is set as PI Point Data Reference, its value cannot be changed through PI Vision Event Table. Moreover, if you try to change the Reason of a closed Event Frame and currently another Event Frame is open,...
J.M. Rodríguez over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

have event frames with multiple start triggers match preview results when the parent start time is adjusted during reconciliation

As a PI System admin, I would like event frames with multiple start triggers to match preview results when the parent Event Frame's start time is adjusted during Event Frame reconciliation. Currently we have to take one of the following actions to...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Meter Type support for REXU-EA

PI Interface for EnergyAxis to support REXU-EA meter types.
leanderb@ntua.com over 3 years ago in PI Interfaces / Other Interfaces 0 No status

BACNet: Add support for Conversion Factor PI Point attribute to PI Interface for BACNet

Add support for Conversion Factor PI Point attribute to PI Interface for BACNet. Note: This was previously Enhancement 118928.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Create a user friendly OPC HDA Tool to replace the current one

No description provided
Gabriel Verreault over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Buffering Manager - add metrics for each buffered interface

When validating/troubleshooting data flow issues, it would be helpful to see metrics on which interfaces are actively sending data to the buffering subsystem via Buffering Manager. If an interface is in a bad state or stopped, it would be obvious ...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Fix PI XMLTool (bundled with PI Interface for OPC XML-DA)

The PI XMLTool that is bundled with the PI Interface for OPC XML-DA does not function with Windows Server 2019 even though the PI Interface for OPC XML-DA itself is documented to function. Can the client tool please be worked on so that it will fu...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

EFGEN multi language support for event frame name

Hi, Existing EFGEN does not seem to support multi language (Double bytes characters) inputs for Event frame name. This result in the event frames names are being recorded in English char only. Would it be possible to implement the multi-langua...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 Declined