To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 395 of 5192

Restrict Batch interface from creating Event Frames using illegal characters

The PI Interface for Rockwell FactoryTalk Batch in processing evt files used a hexadecimal character of 1f in the generation of an event frame. This results in an error when attempting to export the event frame in an xml output.
Nathan Skitt 10 months ago in PI Interfaces / Batch Interfaces 3 No status

Parametrize the "True for x minutes" parameter in event frame analysis

It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Gregory Malek about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Allow to automatically purge Event Frame History

It is currently possible to purge Event Frames using afdiag. I know that version 2018 will bring more filters on that features. It would be nice to be able to configure the purge feature directly from PSE, thus avoiding to have the management of W...
jerome.boudon over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 Declined

Purge EFs using AFDIAG and more search criterias'

You should be able to urge EFs using more complex search criterias' than the ones provide in the latest PI Server 2018 SP3 (StartTime, EndTIme, EF Template). Most important criteria would be EF categories, but also some honorable mentions: 1. EF ...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Upgrade the PI Interface Configuration Utility to a responsive web-based user interface

OSIsoft's migration from PI Interfaces to PI Connectors is very slow. Even after the migration is complete, many PI Interfaces will not be upgraded to PI Connectors, so users will continue to use the PI Interfaces and the PI ICU to configure them....
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Allow PI-ICU to Create/Edit Stored Credentials in Credential Manager

An issue we run into often is that most of the accounts that are used to run our interfaces (mostly OPC DA) are different from accounts we use to configure the interfaces. Because these interfaces run on different domains, we have to store an acco...
Brian Rock over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 4 No status

Support Automatic Failover for PI UFL

Currently UFL only supports two independent instances for redundancy purposes.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 Declined

AutoPointSync for OPC DA should work on 64bit servers.

AutoPointSync for OPC DA does not install or run correctly on 64bit servers. As most new servers are 64bit this would seem to be an essential capability.
zubzub over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

change the default behavior of the OPC DA interface to use /DC

per the OPC DA 2.x spec, the OPC server will call us back for all points that have a changes; even those points where we are polling. We have a switch to disable the callbacks for points that are not set to advise: /DC Can we make that the defau...
Clint Ramsey over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI OPCtoCSV Tool: Subbranch filter depth

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch however it recurses all sub-subbranches. We have an OPC server with around 20k items that we read into ...