To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 395 of 5192

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Output at close option on EFGen

It would be interesting to have an 'Output at close' option on EFGen like we have on a normal Event Frame Generation.
Carlos Castro almost 2 years ago in PI Interfaces / Other Interfaces 1 Declined

Device status tags do not show OPC DA server Invalid client handle errors

When OPC DA interface receives an "Server returned Invalid Client Handle" error, device status tags do not show that error and therefore potential situations where data is not being received by the interface are missed I would be good that device ...
asanzacedo almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Upgrade PI Interfaces for BACnet

In testing of the PI Interface BACNet, the BVRATE value does not reflect the I/O Timeout value, even in the latest version. We are not sure if this behavior was originally intended or not. Please investigate the cause of this behavior and implemen...
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Allow some IF checking for TagPath to see if it exists or has a value before putting it on an Event Frame Attribute.

It would be useful to be able to add tags to Event Frame Attributes that only exist or have a value. This came up with a request to merge Batch and A&E so that Alarm Tags made by the A&E interface can be added to Event Frames made by the B...
Tim Proeber over 2 years ago in PI Interfaces / Batch Interfaces 1 Declined

ModifyDate of Event Frames all get modified with security group changes

When someone makes changes to security groups (add, delete, etc) and these groups have global access to event frames in a database, end result is that all event frames get an identical modifydate for that time. We use this modifydate to detect any...
Dan Coursolle over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

EFGEN - Remove dependency for existing tags for interface to start up.

We recently ran into an issue where a few PI tags were retired, but the corresponding EFGEN interface configuration that used the tags were not retired. On the next reboot, the EFGEN interface would not start back up, since the tags could not be f...
Guest over 2 years ago in PI Interfaces / Other Interfaces 1 Declined

Stay with RAD View

RAD view is easier to use for troubleshooting.
Guest over 2 years ago in PI Interfaces / General 0 No status

Add to performance counter status of notifications rules that are with errors (deleted or renamed analysis )

Today, if any analysis that is used in a claim rule is deleted or renamed, the status of the notifications is still "successful" or "good" but an error remains because the trigger is still using an analysis that was removed or renamed. There is...