Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 395 of 5192

PI OPCtoCSV Tool: Filter by OPC ItemID

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch like the PI APS Connector for OPC DA interface, but unlike the APS Connector, it is not possible to fil...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Make Acknowledged status available within Event Frame

Since we have an EventFrame() function to pull in StartTime, EndTime, and Duration from within an event Frame, it would be useful to also be able to access whether or not the event frame was acknowledged. Use case: If level 1 users have not ackno...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 Declined

PI EFGen interface : allow configuration of events without OS-admin rights

PI EFgen interface is built in such a way that it is not possible to configure events without Windows-Admin rights on the machine hosting the interface. This is not relevant in term of security and we would like to let key-users configure events w...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

PI Interface for Ramp Soak Simulator Data - Update Time Period To Seconds

To simulate data using the PI Interface for Ramp Soak Simulator Data, the ExDesc of the PI Point needs to be of the format: (period, end_value) period is the time in minutes. end_value is the value for the tag at the end of the phase period. Cur...
Mohammed Qasim Asghar 8 months ago in PI Interfaces / Other Interfaces 0 No status

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

efgen

Allow EFGen to use a Mix of PITAG + Text for the Creation of event frame names . Concatenate a Text + PITAG for example
valeman over 3 years ago in PI Interfaces / Batch Interfaces 4 No status

PI BACnet interface: add support for BACnet Setpoint object

Add support for BACnet Setpoint objects in the PI BACnet interface.
Kenneth Reiss over 3 years ago in PI Interfaces / Other Interfaces 1 No status

Update GE iFix interface compatibility information

As an interfaces user, I would like to know which versions of iFIX and Windows Server OS are compatible with the PI Interface for GE iFix so that I can determine whether this interface is suitable for my use case. The last update for this interfa...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 No status

Subsecond Cropping for Improved Timestamp Handling

The OPCDA interface currently can only handle subsceonds by ignoring them as mentioned in "Ignore Subsecond Timestamps" under PI Interface for OPC DA - Data Handling settings. However there are use cases where users would like to simply limit the ...
Mohammed Shahin about 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No status

EMDVB - Add Option to End Procedure EF with batchview.endtime equivalent instead of when it's unloaded from the BOI

Currently the EMDVB interface will not end the parent Procedure level event frame until the batch has been unloaded from the Delta Batch Operator Interface. It is very common for users to leave batches loaded for quite a while which causes batches...
Bill Sublette 9 months ago in PI Interfaces / Batch Interfaces 0 No status