To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

UFL Interface - Increase UFL designer sample data file size limit beyond 50 KB

The UFL designer currently limits the sample data file size to 50 KB. This requires users to truncate their text files until it is below this limit.
Paul Kim almost 4 years ago in PI Interfaces / PI Interface for UFL 1 No status

EFGEN - Allow Zeroth State strings to be used with Digital-type Active Points

When my EFGen Active Point tags have a type of digital, the interface should allow certain digital states to be designated as a Zeroth State.
Guest almost 4 years ago in PI Interfaces / Batch Interfaces 1 No status

PI Interface for SNMP accounting for Dynamic OIDs

Certain MIB files use dynamic indices which make dynamic OIDs. As the interface uses OIDs in the instrument tag manual action is needed to repair it should the OID change. This is particularly prevalent when using the HOST-RESOURCES-MIB, which use...
Guest almost 4 years ago in PI Interfaces / Other Interfaces 3 No status

Add support to schedule AF table lookups at precise times

I need more precise control over the timing of table lookups in AF, specifically the ability to schedule them at exact times (such as midnight) rather than relying on the current minimum refresh interval mechanism. AF table connections currently s...
Janelle Minich over 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Store an OPC Server's "VT_EMPTY" Data Type as a "Bad" in PI Data Archive

When there is a problem within an OPC Server, some Items receives "VT_EMPTY" data type values. PI OPC DA Interface ignores this information, and in PI Data Archive present to users and applications the last valid value - that might be incorrect.
jmalmeida over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No status

Possibility to change units of template based attributes

I have template based elements including analysis that can be used for calculations with a variety of units (tonnes, MWh,...). So it would be great to have the possibility to change the units of template based attributes. At the moment they are fi...
Guest almost 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 5 No status

More customizable filter options for the PI AF Audit Trail

As a user of the PI AF Audit Trail, I would like more customizable filter options.  For example, I would like to be able to query changes "not equal" to a string.
Guest almost 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

AF should react better to unhandled exceptions from a linked table provider

When an OLE DB or ODBC provider returns an unhandled exception for a linked table to the PI AF Application Service , it would be better for it either handle the exception and not crash, or to log the exception, the linked table name and provider n...
Guest almost 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Conversion Factor with PItoPI interface

I would like to use a Conversion Factor for some PI Points that retrieve data via PI to PI. For example, on the source server the data is in volts. I would like to convert this data to kilo volts on the destination server.
Guest almost 4 years ago in PI Interfaces / PI to PI Interface 0 No status

PI UFL Interface get data from FTP Server

No description provided
Guest almost 4 years ago in PI Interfaces / PI Interface for UFL 0 No status