Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 890 of 5273

Allow AF Table to use subsecond timestamps for DateTime columns

Allow DateTime columns in AF Tables to show subseconds Events come in with very similar timstamps except subsecond level. For example 2025-01-14 03:55:01.533 XYZ and 2025-01-14 03:55:01.833 ABC but in AF Table columns subsecond is not show so both...
Guest about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

"Connect As" to the Analysis Service From PI System Explorer

The "Connect As" feature only changes the Asset Framework Connection and still uses the user who runs the application to connect to the Analysis service. This causes a confusion for end users as they cannot perform their analyses operations (e.g. ...
Mohammed Qasim Asghar 3 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Reduce Number of Point Sources for PI Connector for PI System Health

PI Connector for PI System Health creates a LOT of different point sources for the Pi points it creates on the Data Archive. Some customer may prefer to not have so many point sources show up for one interface/connector. Adding a method to reduce/...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status

Warm and cold PI Connector for OPC UA failover

Currently only hot failover is featured for the PI Connector for OPC UA but this creates a lot of strain on the data sources. We need to be able to select warm/cold failover mechanism.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Possibility to change units of template based attributes

I have template based elements including analysis that can be used for calculations with a variety of units (tonnes, MWh,...). So it would be great to have the possibility to change the units of template based attributes. At the moment they are fi...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 5 No status

More customizable filter options for the PI AF Audit Trail

As a user of the PI AF Audit Trail, I would like more customizable filter options.  For example, I would like to be able to query changes "not equal" to a string.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

AF should react better to unhandled exceptions from a linked table provider

When an OLE DB or ODBC provider returns an unhandled exception for a linked table to the PI AF Application Service , it would be better for it either handle the exception and not crash, or to log the exception, the linked table name and provider n...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Create/Write to Child Attributes

I would like to be able to write to Child attributes with the UFL connector using the StoreInElement function. Currently, it seems that the Connector cannot write to or create an attribute with a path like: ..\Element|ParentAttribute|ChildAttribu...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

PI UFL Connector Event Frame Generator enhancement and bugfixes

Currently it is not possible to create an event frame from the PI UFL Connector linked to an existing element, despite the documentation does not specifically mention this restriction, you can only link the new event frame to an element created wi...
Andy over 3 years ago in PI Connectors / PI Connector for UFL 2 No status

Redundancy for PI Connector Relay

Operating in a validated pharmaceutical industry, when making use of a comprehensive data/asset centralizing approach, we require the PI Connector Relay to be redundant or highly available. We are currently in the obligation to deploy the PI Conne...
Christian Leroux over 3 years ago in PI Connectors / Other specific PI Connector 0 No status