Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 456 of 5192

PI AF Template Versioning

Allow for PI AF templates to be version controlled. Include the ability to revert to previous template version, or continue to use old versions for specific elements. This will reduce the risk of deployment and improve change/release management pr...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 3 No status

Make the Agent recrawl the AF/PI Point database from scratch

Make the agent recrawl the AF/PIPoint database from scratch every now and again and update its cache if required. I think this is what PI Vision does, so it doesn't have these limitations.
Guest 4 months ago in PI to CONNECT / General 0 No status

Allow Multiple Data Archives per PI to CONNECT Agent

Allowing data transfer for tags from multiple PI Data Archives with one agent will help to cut down on the number of agent services, and therefore machines, that need to be involved to send data from PI to CONNECT.
Guest over 3 years ago in PI to CONNECT 0 In development

Monitor PI to CONNECT connection

Sometimes, the PI to CONNECT agent seems to have some interruption in replicating data from a PI Data Archive into CONNECT data services. It would be beneficial to have some more monitoring options (in addition to what is available through the CON...
Guest over 3 years ago in PI to CONNECT 1 In development

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Ability to embed substitution parameters

I would like the ability to embed a substitution parameter within another substitution parameter. For example, in the following Configuration String: \\%Server%\%@||TagName% I would like to replace with a substitution parameter
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 3 No status

Allow selective AF Database indexing

The PI to CONNECT agent will index the whole AF server. On big ones, this is tedious (one took more than 12 hours) - would prefer to have the ability to choose either on the agent or from CONNECT which AF databases to index.
Guest over 2 years ago in PI to CONNECT / General 1 No status

Add additional Analysis Search Criteria options to PSE Management

It would be helpful if you could search by Element Category or Element Description when searching for Analyses in PSE. My setup is 5 templates (CHW, Water, HW, Electric, Steam), each of which have accounts that can come from 5 different sources (s...
Kelsey Bobeck over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Increase the sub seconds to be more that 3 decimal places in PSE UI

We faced an issue with thinking the formula DR time series data in PI System Explorer was duplicating results but that was because the sub seconds were not showing and there were difference in the sub seconds for the two results which we thought w...
Sakina AlHamood over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status