To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Prevent Analysis calc failure for attribute not found

If the same analysis is trying to be used for multiple templates, there will be times when some attributes are not available from a template - this will cause the analysis to fail. Even when the difference in attributes is known and attempted to b...
Dan Benedict about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Allow OMF Health Authentication on PI Interfaces to Negotiate

Currently the OMF Health feature of PI interfaces only allows the interface to connect to the PI Web API OMF endpoint using Basic authentication. It would be good to see negotiate and windows authentication as an option like PI Adapters have to co...
Brian Rock about 1 year ago in PI Interfaces / General 0 No status

Maintain trace colors when trending in PSE

When trying to quickly trend and compare data in AF, it is made more difficult by the fact that the colors are not maintained when showing/hiding traces. For example, if I have attributes A, B, and C, they will initially show up as blue, red, and ...
Kelsey Bobeck about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Add TCP option to PI UFL Interface

Currently the only two options are file reading or a serial interface. But what if you have ASCII data streaming from a TCP/telnet source? The configuration would be almost the same as serial - for the connection, rather than a serial port, just n...
John Alessio about 1 year ago in PI Interfaces / PI Interface for UFL 0 No status

Search functionality in PSE to find Analyses within hierarchy

Options to locate analyses seem absent or limited to solutions outside of PSE. It would be convenient to have a feature that lets me search for an analysis, and have it return its location in hierarchy (whether it writes to a tag or not).
Matthew Farah over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

PSE : Add Analysis loading progress bar

I would like to see a progress bar or some indication in PSE that it is working on loading the analyses to run when the service stops and restarts. We have around a million analyses created and it can take time to start them all up when we fail ov...
Jonathan Gibbs about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

PSE - Add analysis function that returns a count of children

I would like a new function in PSE in the analyses to count the number of children that an element has. I could use this information in an analysis that I want to run. There is a workaround where I can create a separate rollup function to try to c...
Jonathan Gibbs about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

PSE Management: Add ability to see what type of analyses is queued / completed / running

In PSE, I can go to the Management section, Analyses tab and see a list on the right side of analyses that are queued or completed or running. I cannot however tell what these analyses are doing. I would like to have the ability to right click an ...
Jonathan Gibbs about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

PI Asset Framework - Add string "join" function to Asset Analytics

Please add a "Join" function in Asset Analytics to combine string values in an array into one string. This would allow us to combine a varying number of outputs into one single variable that can be written to one attribute. Then, when that output ...
Gregory Malek over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth almost 4 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status