Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 496 of 5192

Password Protection For AF Databases

For AF databases we want to go beyond the AF security configuration and add password protection layer for databases.
Mohammed Qasim Asghar almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Ability to disable recalculation at the Database level in AF

Currently backfilling and recalculation are only enabled and disabled at the global and element level. There are instances where users of Asset Analytics, particularly when it comes to event frames, experience automatic recalculation upon a servic...
zachary cmelak almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Taq quality based holding last good value not working

Important element attributes for trend are configured in PI AFDB with multiple inputs A/B/C etc, for validation and reliabile trending. However it is observed that bad quality on any of the input signals makes the final output bad by default. This...
AK about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Element create version in Bulk

When right-click an element in system explorer, then create version, I need to be able to do it in bulk and not element by element.
Gilbert Nassif over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Change column order in System Explorer Attributes tables

Allow the user to change the order of columns that appear in the Attributes table in System Explorer. Currently, as columns are "checked" to be shown via Column Visibility setting, they appear in a predefined order and cannot be changed. For examp...